Datos del producto:
|
| Rango: | 0 - 100% LIE | Resolución: | El 1% de la LEL |
|---|---|---|---|
| Configuración de alarma del instrumento.: | Nivel 1 - 10% LEL, Nivel 2 - 50% LEL | Gas medido: | Gas de hidrocarburo combustible |
| Vida útil: | Certificado de fábrica por 3 años | Emplazamiento industrial: | 24 - 30 meses |
| Temperatura de funcionamiento: | -20 ℃ a +50 ℃ | Presión: | Entre 80 y 120 kPa |
| Resaltar: | RIKEN combustible gas sensor,LEL catalytic combustion sensor,YJJ NC-6264A gas detector |
||
Product Description:
YJJ NC-6264A RIKEN0-100% LEL Catalytic Combustion LEL Combustible Gas Sensor
Features:
I. Basic Parameters
Detection Principle: Catalytic bead combustion type (platinum wire catalytic element)
Range: 0 - 100% LEL (calibrated with methane CH₄)
Resolution: 1% LEL. Alarm settings of the instrument: Level 1 - 10% LEL, Level 2 - 50% LEL
Measured Gas: Methane, Propane, Butane, Various Alkanes, Hydrogen H₂, etc. Combustible Hydrocarbon Gases
Service Life: Original factory specification 3 years, industrial site regular replacement 24 - 30 months
Operating Environment
Working Temperature: -20℃ - +50℃
Humidity: 0 - 95% RH (no condensation water vapor)
Pressure: 80 - 120 kPa
Power Supply: Detection instrument built-in voltage stabilizing driver (Whisham bridge circuit), diffusion type intake
Compatible Models (Riken Portable Four-Component Detector) GX-2001/GX-2003/GX-2009/GX-2012/GX-6000/GP-01/GP-03/Gas Tracer
The suffix NC-6264AZP represents a modified anti-poisoning version, resistant to silicon and organic solvent poisoning, and with a longer lifespan.
II. Product Applications
1. Equipment Compatibility
As the original probe for the Riken series of portable multi-gas detectors, it can be combined with three sensors - O₂, CO, and H₂S - to achieve four-in-one gas inspection.
2. Industry Applications
Petrochemicals, refineries: Pipeline and storage tank area inspections to prevent combustible leakage and explosion
Gas utilities / gas stations: Leak detection in natural gas and liquefied gas pipelines
Ship cabins, underground coal mines: Monitoring of methane and flammable/explosive gases in confined spaces
Painting workshops, lithium battery factories: Monitoring of solvent evaporation and flammable vapors
Wastewater treatment plants, sealed pits and wells: Safety detection of methane (methane) concentration
Specifications:
| Detecting gas | Combustible hydrocarbon gas |
| Range | 0 - 100% LEL |
| Methane explosion lower limit | 4.4% VOL |
| Power supply | Rated DC 3V |
| Peak | 50mA |
| Repeatability error | T90 ≤ 12s |
![]()
Persona de Contacto: Miss. Xu
Teléfono: 86+13352990255