logo
Inicio ProductosSensor del gas

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

Certificación
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
Estoy en línea para chatear ahora

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors
YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

Ampliación de imagen :  YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

Datos del producto:
Lugar de origen: Gran Bretaña
Nombre de la marca: YJJ
Número de modelo: Dcel H2S
Pago y Envío Términos:
Cantidad de orden mínima: 1
Precio: Negociable
Detalles de empaquetado: Enlatado
Tiempo de entrega: 5 dias
Condiciones de pago: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacidad de la fuente: 2200

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

descripción
Resolución: < 0,1 ppm Repetibilidad: < ±2%FS
Resistencia de carga recomendada: 10Ω Temperatura de funcionamiento: -30 °C ~ +50 °C
Rango de humedad: 15% - 90% de HRC Rango de presión: 800 - 1200 mbar
Vida y garantía: Vida útil prevista 24 meses. Alfiler: 3 alfileres
Resaltar:

H2S gas sensor 0-100ppm

,

portable hydrogen sulfide detector

,

electrochemical gas sensor with warranty

Product Description:

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors

 

Features:

I. Basic Information

Model: DceL-H2S (Ultra-thin, low-profile 3-pin electrochemical sensor, compatible with 4-series sensor size, thickness halved)

Detected gas: Hydrogen Sulfide (a highly toxic, rotten egg-like gas)

Principle: Three-electrode electrochemical principle, 0V bias, no power supply required

Positioning: Industrial-grade portable / fixed detection instrument dedicated, ultra-thin volume, high stability, anti-methanol interference

II. Core technical parameters (mainstream 0-100ppm version)

Measurement range: 0-100 ppm (also available 0-300ppm version)

Maximum overload: 200 ppm

Sensitivity output: 140±30 nA/ppm

Baseline drift: ±2ppm H₂S equivalent in clean air

Response time: T90 < 30 seconds

Resolution: < 0.1 ppm (depending on the backend circuit)

Repeatability: < ±2%FS

Recommended load resistance: 10Ω

Operating temperature: -30℃ ~ +50℃

Humidity range: 15% - 90% RH (no condensation)

Pressure range: 800 - 1200 mbar

Life & Warranty: Expected lifespan 24 months, original factory warranty 24 months

Core advantages: Low cross-interference with methanol, temperature drift resistance, rapid recovery, strong environmental adaptability

Pin: 3 pins, ultra-thin, low-profile packaging, compatible with 4-series sensor mechanical size

III. Main applications (compatible with your existing sensor procurement system)

Petrochemical / Oil and Gas Extraction: Oil fields, drilling platforms, refineries, natural gas pipelines H₂S leakage detection

Wastewater Treatment / Municipal: Sewage plants, septic tanks, garbage stations, underground pipelines sulfur dioxide monitoring, to prevent poisoning and explosion

Mining and Metallurgy: Coal mines, non-ferrous metal mines underground toxic gas inspection

Portable gas detector: Can directly replace H₂S sensors of brands such as METTLER TOLEDO, SENKO

Fixed gas alarm: Online monitoring in industrial plants, chemical workshops

Livestock / Biogas Industry: Biogas tanks, livestock farms sulfur dioxide concentration detection

Limited space operations: Enclosed tanks, cellars, pipeline maintenance before safety inspection

 

Specifications:

Measurement Range 0-100 ppm
Also available 0-300ppm
Maximum overload 200 ppm
Sensitivity output 140±30 nA/ppm
Baseline drift ±2ppm H2S equivalent in clean air
Response time T90 < 30 seconds

 

YJJ DceL H2S 0-100ppm Electrochemical Hydrogen Sulfide Gas Sensor Portable Gas Detectors 0