logo
Inicio ProductosSensor del gas

YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

Certificación
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
Estoy en línea para chatear ahora

YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring
YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

Ampliación de imagen :  YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

Datos del producto:
Lugar de origen: Porcelana
Nombre de la marca: YJJ
Número de modelo: 3NO-2000CT 058-3000-100
Pago y Envío Términos:
Cantidad de orden mínima: 1
Precio: Negociable
Detalles de empaquetado: Enlatado
Tiempo de entrega: 5-8 días
Condiciones de pago: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacidad de la fuente: 2200

YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

descripción
Gas de detección: No Rango: 0 a 2000 ppm
Resolución: 1 PPM Sensibilidad: 0.10 ± 0,02 μA/ppm
Tiempo de respuesta T90: ≤ 25 segundos Señal de referencia: 0 - +12 ppm
Desviación de línea de base: < 30 ppm Linealidad: 0 - 2000 Ppm
Resaltar:

Electrochemical NO sensor for flue gas

,

Nitric oxide sensor emission monitoring

,

YJJ 3NO-2000CT gas sensor

Product Description:

YJJ 3NO-2000CT 058-3000-100 Electrochemical Nitric Oxide NO Sensor Special Use Flue Gas Emission Monitoring

 

Features:

3NO-2000CT is a three-electrode electrochemical nitric oxide (NO) sensor, primarily used for quantitative detection of NO concentrations ranging from 0 to 2000 ppm. It is suitable for harsh industrial emission and environmental monitoring conditions and can directly replace the mainstream 3-series NO sensors. It features linear output, fast response, and good long-term stability.
Core parameter description (20℃, standard atmospheric pressure)
Parameter Value Remarks
Detected gas Nitric oxide (NO) Three-electrode electrochemical principle
Range 0-2000 ppm Maximum overload 5000 ppm
Sensitivity 0.10 ± 0.02 μA/ppm (typical value 0.10 μA/ppm) Current signal is proportional to the concentration, and the signal is a positive output
Response time (T90) ≤ 25s Quickly captures concentration changes
Baseline (20℃) 0 - +12 ppm Initial zero deviation is small
Baseline drift (-20℃ to 50℃) < 30 ppm Controllable drift in a wide temperature range
Resolution 1 ppm Meet the routine monitoring accuracy
Linearity Linear With bias + 300 mV, a corresponding bias circuit is required
Operating temperature -20℃ to 50℃ Adapt to industrial and outdoor environments
Pressure range 1 standard atmosphere ± 10% Compatible with routine conditions
Humidity range 15% - 90% RH (no condensation) Prevent the influence of condensation on performance
Long-term stability < 2% signal value / month Reliable long-term monitoring data
Service life 3 years (in air) Storage temperature 10℃ to 30℃
Safety integrity Maximum open-circuit voltage 1.3V, maximum short-circuit current < 1mA Compatible with explosion-proof scenarios
Main application
Industrial flue gas emission monitoring: Used for real-time monitoring of NO emissions from fixed pollution sources such as coal-fired power plants, waste incineration plants, and nitric acid plants, meeting the continuous monitoring requirements of environmental protection regulations for chimney emissions, and can work stably in high-concentration and high-dust harsh conditions.
Environmental air quality detection: Integrated into air quality monitoring stations or mobile monitoring equipment, used for grid-based monitoring of NO concentrations in urban and industrial parks, assisting in pollution source tracing and governance decisions, providing data support for environmental quality assessment.
Industrial safety and process control: In production processes involving NO such as chemical synthesis, metal processing, and welding, real-time monitoring of leakage and process gas concentrations, ensuring personnel safety and production stability, and avoiding health hazards and safety accidents caused by NO leakage.
Equipment and instrument matching: As the core sensing element, embedded in portable NO detectors, online analysis instruments, etc., compatible with explosion-proof, outdoor, etc. complex conditions, supporting rapid replacement of mainstream 3-series sensors, reducing maintenance costs.

 

Specifications:

Overload 0-2000 PPM
Response time 25 s
Size 20 x 16.5
Sulfur dioxide detection range 0-50ppm
Sensitivity 450-750 na/PPM

 