logo
Inicio ProductosSensor del gas

4CL 3-Electrode Electrochemical Chlorine (Cl₂) Gas Sensor For Typical Applications

Certificación
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
Estoy en línea para chatear ahora

4CL 3-Electrode Electrochemical Chlorine (Cl₂) Gas Sensor For Typical Applications

4CL 3-Electrode Electrochemical Chlorine (Cl₂)  Gas Sensor For Typical Applications
4CL 3-Electrode Electrochemical Chlorine (Cl₂)  Gas Sensor For Typical Applications

Ampliación de imagen :  4CL 3-Electrode Electrochemical Chlorine (Cl₂) Gas Sensor For Typical Applications

Datos del producto:
Lugar de origen: EE.UU
Número de modelo: 4CL
Pago y Envío Términos:
Cantidad de orden mínima: 1 Uds.
Precio: Negociable
Detalles de empaquetado: Embalaje estándar
Tiempo de entrega: 5-8 DÍAS LABORALES
Condiciones de pago: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacidad de la fuente: 5000 piezas

4CL 3-Electrode Electrochemical Chlorine (Cl₂) Gas Sensor For Typical Applications

descripción
Rango de medición: 0~10 ppm Sobrecarga máxima: 100 ppm
Resolución: 0.1 ppm Sensibilidad: 0,60 ± 0,15 µA/ppm
Compensación de línea de base: -0,2 a +0,2 ppm Resistencia de carga recomendada: 33 Ω
Resaltar:

3-electrode chlorine gas sensor

,

electrochemical Cl₂ sensor

,

gas sensor for typical applications

 

                                4CL 3-Electrode Electrochemical Chlorine (Cl₂) Gas Sensor For Typical Applications

 

 

Features:

  • Hassle - free Operation: No bias voltage is needed during use, and it can work normally with a recommended 33 Ω load resistor, simplifying the design of matching circuits for terminal equipment.
  • Stable and Reliable Performance: The monthly signal drift is less than 2%, and the zero shift in the temperature range of +20 °C to +40 °C is within 0.2 ppm equivalent, ensuring long - term detection accuracy.
  • Flexible Installation: With a light weight of about 5 grams and no restrictions on installation orientation, it can be integrated into various types of monitoring equipment without being constrained by installation space and angle.
  • Durable Service Life: It has a 2 - year expected operating life in air and a 6 - month storage life in a sealed container, which can meet the long - term use needs of most general - purpose monitoring scenarios.

Application:

 

Typical Applications: It is mainly used in portable chlorine gas detectors, fixed chlorine gas leak monitoring systems in industrial workshops, and environmental monitoring equipment related to chlorine gas use, helping to promptly warn of chlorine gas concentration exceeding the standard.

 

 

Measurement Performance Target Gas Chlorine (Cl₂)
  Measurement Range 0 - 10 ppm
  Maximum Overload 100 ppm Cl₂
  Resolution 0.1 ppm (electronics dependent)
  Sensitivity 0.60 ± 0.15 µA / ppm
  Response Time (T90) < 60 seconds
  Baseline Offset (Clean Air) -0.2 to +0.2 ppm equivalent
  Zero Shift (+20 °C to +40 °C) < 0.2 ppm equivalent
  Repeatability 2% of signal
  Linearity Linear
Electrical Properties Recommended Load Resistor 33 Ω
  Bias Voltage Not required
Mechanical Properties Casing Material ABS
  Weight Approximately 5 g
  Installation Orientation Any
Environmental Requirements Operating Temperature Range -20 °C to +50 °C
  Operating Pressure Range 1 atm ± 10%
  Operating Humidity Range 15% - 90% RH, non - condensing
Lifespan Long - term Output Drift < 2% signal drift per month
  Expected Operating Life 2 years in air
  Recommended Storage Temperature 0 °C to 20 °C
  Storage Life 6 months in sealed container

 