HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection
HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Ampliación de imagen :  HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Datos del producto:
Lugar de origen: Reino Unido
Nombre de la marca: Alphasense
Número de modelo: Hcn-a1
Pago y Envío Términos:
Cantidad de orden mínima: 1
Precio: Negociable
Detalles de empaquetado: Paquete estándar
Tiempo de entrega: 3-5 trabajos de día
Condiciones de pago: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacidad de la fuente: 10000PCS/mes

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

descripción
Rango de medición: 100 ppm Sensibilidad: 30ppm
Corriente de punto cero: <±2 ppm Resolución: <0,05 ppm
Resaltar:

hydrogen cyanide gas sensor

,

chemical leak detection sensor

,

HCN-A1 gas sensor

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

 

The HCN-A1 electrochemical hydrogen cyanide gas sensor is commonly used in chemical leak detection, environmental monitoring, and other applications.

 

Physical and usage cycle parameters

Dimensions Diameter 20.2mm, Overall height 16.5mm (including label), Dimensional tolerance ±0.15mm
Weight <6 grams
Operating life Output signal drops to 80% of initial value in over 12 months, official 12-month warranty
Storage period 6 months in a sealed environment at 3-20℃

 

Environment adaptation parameters

Operating temperature -30~50°C; sensitivity at -20°C is 75-95% of that at 20°C, and sensitivity at 50°C is 105-120% of that at 20°C.
Operating humidity 15-90% RH (continuous operation)
Operating pressure 80-120 kPa
Temperature effect on zero point zero-point change relative to 20°C at -20°C < 0-1 ppm; zero-point change relative to 20°C at 50°C < ±1 ppm.

 

Electrical and interference related parameters

Recommended load resistor 10 - 33Ω
Bias requirement No additional bias voltage required

 

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection 0

 