Datos del producto:
Lugar de origen: Rusia
Número de modelo: Mipex-02-3-I-1-1A(40)
Pago y Envío Términos:
Cantidad de orden mínima: 1
Precio: Negociable
Detalles de empaquetado: caja de papel
Tiempo de entrega: 3-5 días de trabajo
Condiciones de pago: L/C, D/A, D/P, T/T, Western Union, Moneygram
Capacidad de la fuente: 5000pcs

Mipex-02-3-I-1-1A(40)Non Dispersive Infrared (NDIR) Methane Gas Sensor For Hazardous Area Monitoring

descripción
Método de muestreo de gas: Difusión Método de operación: Infrarrojo no dispersivo (NDIR)
Gases objetivo: CH$₄$; CH₄/CH₄ + C₃H₈; C₃H₈; CO₂ Presión atmosférica / kPa: 80...120
Tiempo de calentamiento (segundo): ≤120 Dimensiones externas / mm: 20,3×16,6
Resaltar:

NDIR methane gas sensor

,

hazardous area gas sensor

,

methane sensor with warranty

 

               Mipex-02-3-I-1-1A(40)Non Dispersive Infrared (NDIR) Methane Gas Sensor For Hazardous Area Monitoring

 

 

Product Uses:

  • Hazardous Area Monitoring: It is ideal for use in explosive - hazardous areas (Groups I and II according to IEC 60079 standards), such as in the mining, oil and gas, and chemical processing industries. It can continuously monitor the gas concentrations in these environments to ensure safety.
  • Environmental Monitoring: Suitable for detecting the concentration of carbon dioxide in industrial buildings or regulated environments, which helps in assessing the air quality and its impact on the environment and human health.
  • Gas Analysis Systems: Can be easily integrated into gas analysis solutions for industrial or laboratory applications, providing real - time data on gas concentrations, which is of great significance for process control and research.

Product Features:

  • Small - Sized Design: The small size of the sensor (diameter: 20.2 mm to 22 mm, depending on the housing type) allows for easy integration with gas analysis instruments and monitoring systems in hazardous areas.
  • High Sensitivity and Accuracy: It uses dual - wavelength infrared absorption to measure gas concentrations selectively, eliminating interference from water vapor or optical pollution, thus ensuring high - sensitivity and accurate detection of target gases.
  • Wide Operating Range: The operating temperature range can be - 40℃ to +60℃ (depending on the housing type), and it can work in environments with humidity levels up to 98% relative humidity, showing strong adaptability to different environmental conditions.
  • Stability and Reliability: Made of durable materials such as vibration - resistant stainless steel and Lexan™ plastic (depending on the housing type). It has an IP54 protection rating, which is resistant to dust and water ingress (with an optional dust filter), ensuring long - term stable operation.
  • Long Service Life: Designed to have an expected service life of up to 10 years, which ensures long - term reliability with less maintenance, reducing the overall cost of use.
  • Easy Calibration: The Mipex - 02 includes an integrated storage unit with a precise control unit for calibration constants, and it supports direct calibration and range adjustment, making it very suitable for both industrial and laboratory equipment.
  • Low Power Consumption: It is characterized by low power consumption during operation, which reduces the overall power requirements of the system, and is suitable for applications where power supply is limited.
  • Compliance with Standards: It meets the IEC 60079 - 0 and IEC 60079 - 11 standards for electrical equipment safety, and is approved for use in Class I, Division 1 environments (UL 913, CAN/CSA C 22.2), ensuring its safety and reliability in hazardous environments.

 

Gas Sampling Method Diffusion
Operation Method Non - Dispersive Infrared (NDIR)
Target Gases CH₄; CH₄/CH₄ + C₃H₈; C₃H₈; CO₂
Relative Humidity for Operation, Storage and Transportation Maximum 98%
Atmospheric Pressure / kPa 80...120
Warm - up Time (Second) ≤120
External Dimensions / mm Φ20.3×16.6 (Excluding Protrusions)
Housing Material Corrosion - Resistant Lexan™ Polycarbonate

 

Mipex-02-3-I-1-1A(40)Non Dispersive Infrared (NDIR) Methane Gas Sensor For Hazardous Area Monitoring 0

Contacto
ShenzhenYijiajie Electronic Co., Ltd.

Persona de Contacto: Miss. Xu

Teléfono: 86+13352990255