logo
Inicio ProductosSensor oxígeno-gas

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Certificación
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
CHINA ShenzhenYijiajie Electronic Co., Ltd. certificaciones
Estoy en línea para chatear ahora

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices
YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Ampliación de imagen :  YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Datos del producto:
Lugar de origen: Gran Bretaña
Nombre de la marca: YJJ
Número de modelo: O2-C2
Pago y Envío Términos:
Cantidad de orden mínima: 1
Precio: Negociable
Detalles de empaquetado: Paletizado
Tiempo de entrega: 5-8 días
Condiciones de pago: L/C, D/A, D/P, T/T, Western Union, Moneygram
Capacidad de la fuente: 2200

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

descripción
Rango de medición: 0 - 30% de concentración de oxígeno Salida actual: 80 a 120 μA
Resistencia a la carga: 47 - 100 ohmios Tiempo de respuesta: T90 (de 20.9% a 0%) <45 segundos
Temperatura de funcionamiento: -30 a 55℃ Rango de humedad: 5 - 95% RH
Rango de presión: 80 - 120 KPa Tamaño: 20.3 × 23 mm
Resaltar:

electrochemical oxygen sensor 0-30% range

,

oxygen alarm device sensor

,

YJJ O2-C2 oxygen sensor

Product Description:

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

 

Features:

Main parameters of the O2-C2 oxygen sensor are as follows:

Measurement range

0 - 30% oxygen concentration

Output signal

Current output: 80 - 120 μA (at 22℃, 20.9% oxygen)

Load resistance: 47 - 100 ohms

Response time

T90 (from 20.9% to 0%) < 45 seconds

Environmental adaptability

Operating temperature: -30 to 55℃

Humidity range: 5 - 95% RH

Pressure range: 80 - 120 kPa

Other features

Size: Φ20.3 × 23mm

Weight: < 18g

Storage period: 6 months (sealed preservation)

Linear error: ±0.6% of the full range

Application fields: Oxygen alarm device, atmosphere analyzer

 

Specifications:

Range 0 - 30 ppm
Sensitivity 1.9 ± 0.8 μA/ppm (at 20℃)
Baseline range -0.2 to 2.5 μA (@20℃)